Image #3  Foot Fuji S-Value: 175 Range: 75-200 (no adjustmen…

Image #3  Foot Fuji S-Value: 175 Range: 75-200 (no adjustment needed) Under 75 Over-exposed (- Technique)  Over 200 Under-exposed (+ Technique) To make image optimal I will: Move lead anatomical marker within the light field Position lower leg parallel with IR (superimpose talar domes) Increase flexion of foot Decrease technique

Image #15                                               *ma…

Image #15                                               *magnified w/out lines To make image optimal I will: Flex skull forward until AML is perpendicular to the IR Decrease angle of CR Extend skull backward until AML is perpendicular to the IR Correct the rotation

Image #11 Fuji S-Value: 65 Range: 75-200 (no adjustment need…

Image #11 Fuji S-Value: 65 Range: 75-200 (no adjustment needed) Under 75 Over-exposed (- Technique)  Over 200 Under-exposed (+ Technique) To make image optimal I will: Decrease technique Increase the CR angle Increase the technique Place anatomical marker out of anatomy of interest

Image #15 Fuji S-Value: 293 Range: 100-400 (no adjustment ne…

Image #15 Fuji S-Value: 293 Range: 100-400 (no adjustment needed) Under 100 Over-exposed (- Technique)  Over 400 Under-exposed (+ Technique)                                          *magnified w/out lines To make image optimal I will: Increase technique Open the collimation to include anatomy of interest Direct the CR up (superior) to C4 Increase angle of the CR

Image #2 Fuji S-Value: 134 Range: 75-200 (no adjustment need…

Image #2 Fuji S-Value: 134 Range: 75-200 (no adjustment needed) Under 75 Over-exposed (- Technique)  Over 200 Under-exposed (+ Technique) To make image optimal I will: Increase medial (internal) rotation Increase lateral (external) rotation Keep technique the same Move the CR slightly distal to proper point

Image #6  Lateral Ankle Fuji S-Value: 67 Range: 75-200 (no a…

Image #6  Lateral Ankle Fuji S-Value: 67 Range: 75-200 (no adjustment needed) Under 75 Over-exposed (- Technique)  Over 200 Under-exposed (+ Technique) To make image optimal I will: Increase collimation (cone down) Decrease technique Increase flexion of ankle Increase technique

Image #17 Fuji S-Value: 226 Range: 100-400 (no adjustment ne…

Image #17 Fuji S-Value: 226 Range: 100-400 (no adjustment needed) Under 100 Over-exposed (- Technique)  Over 400 Under-exposed (+ Technique) Image techniques: Image is correctly exposed Image is over-exposed Image is under-exposed Trabecular markings and cortical outlines are well visualized