Janet is a bright ten-year-old girl who frequently complains of being bored. During silent independent reading each day, she leaves her book unopened on her desk, and generally will leave her seat and disrupt the other students around her. The teacher calls her up to the front of the classroom and reprimands Janet each day, then sends her back to her seat. Janet soon leaves her seat again. If you were conducting a functional behavior assessment of Janet, what label would you use for the fact that Janet gets to alleviate her boredom by getting called up in front of the class and reprimanded by the teacher?
Determine the maximum locked-rotor current for a 30-hp, 415-…
Determine the maximum locked-rotor current for a 30-hp, 415-V, 3-phase motor has a nameplate kilovolt-ampere code letter A.
According to: For a 100,000 ft2 school if the initial calcu…
According to: For a 100,000 ft2 school if the initial calculated load was 1,300,000 VA the calculate the overall load is:
Consider a 16-unit office building where each unit contains…
Consider a 16-unit office building where each unit contains one A/C rated at single phase 5hp 208V The full load current for one would be: One motor load would then be: The total load for all these A/C would be:
Consider a 11-unit office building where each unit contains…
Consider a 11-unit office building where each unit contains one A/C rated at single phase 5hp 200V The full load current for one would be: One motor load would then be: The total load for all these A/C would be:
Consider a branch circuit for 14kW fixed electric space heat…
Consider a branch circuit for 14kW fixed electric space heater w/ 5.4 Amp blower motor 208 Volt 3-phase What is an adequate overcurrent protection size rating?
Consider the following Transformer Which is a 5 kVA transfo…
Consider the following Transformer Which is a 5 kVA transformer used to step down 480 to 120 volts to supply a single-phase two-wire circuit The calculated primary full load current for this transformer is The maximum primary over current would be The calculated secondary full load current for this transformer is The maximum secondary over current would be
Consider the following three-phase short circuit: With A….
Consider the following three-phase short circuit: With A. 1000 kVA Transformer with 480V, 3Ph, 3.5% Z B. 25′ – 500kcm copper, 3 single conductor 6 per phase service entrance in steel conduit C. 2000 A switch with 2000 A fuse x1 Fault X1 D. 400 A switch with 400 A fuse E. 50′ – 500kcm copper, 3 single conductor feeder cable in steel conduit x2 Fault X2 Using Point-to-Point calculation (using the given impedance at 100%) The total current for short circuit sym RMS at Fault X1 is The total current for short circuit sym RMS at Fault X2 is