A pin-connected wood truss is loaded and supported as shown. Determine the axial force produced in member GH if PB = 700 lb, PC = 2,000 lb, PD = 2,600 lb, L = 6 ft, and h = 8 ft. Positive choices indicate tension. Negative choices indicate compression.
Use APA Technical Note Q225 entitled Load-Span Tables for AP…
Use APA Technical Note Q225 entitled Load-Span Tables for APA Structural-Use Panels and ASD procedures to answer the following question.The spacing of rafters in a roof is 12-in. o.c. Roof dead load = 12 psf. Snow load = 73 psf. Roof sheathing is to be an APA rated plywood STRUCTURAL I sheathing, and panels are to be oriented in the weak direction. The load is governed by deflection limits of L/360 for snow load and L/240 for total load. Only consider these limits. Assume multi-span, normal duration of load, dry conditions, and panels 24 inches or wider. Would a panel with a span rating of 32/16 be adequate?
A wood member is loaded as shown. Using ASD, determine the a…
A wood member is loaded as shown. Using ASD, determine the adjusted tension strength, Ft’. Assume normal temperatures, no incising, and that all loads act in the directions shown. Ignore the weight of the member.Load:PD = 3,500 lbPL = 0 lbPLr = 0 lbPS = 0 lbPR = 0 lbPW = 5,000 lbPE = 9,000 lbQD = 0 lbQL = 2,000 lbQLr = 1,000 lbQS = 1,500 lbQR = 2,500 lbQW = 0 lbQE = 0 lbSpan:L = 14 ft Member size:4 x 8 Stress grade and species:No. 2 Douglas Fir-Larch Unbraced length:lu = L/2 = 7 ft Moisture content:MC < 19 percent
A wood member is loaded as shown. Using ASD, determine the a…
A wood member is loaded as shown. Using ASD, determine the adjusted bending strength, Fb’. Assume normal temperatures, no incising, and that all loads act in the directions shown. Ignore the weight of the member.Load:PD = 3,500 lbPL = 0 lbPLr = 0 lbPS = 0 lbPR = 0 lbPW = 5,500 lbPE = 7,000 lbQD = 2,000 lbQL = 3,500 lbQLr = 4,500 lbQS = 1,000 lbQR = 0 lbQW = 0 lbQE = 0 lbSpan:L = 8 ft Member size:4 x 10 Stress grade and species:No. 1 Douglas Fir-Larch Unbraced length:lu = 0 ft Moisture content:MC > 19 percent
Which statements are valid about Diagram 0?
Which statements are valid about Diagram 0?
A pin-connected wood truss is loaded and supported as shown….
A pin-connected wood truss is loaded and supported as shown. Determine the axial force produced in member GH if PB = 1,000 lb, PC = 2,100 lb, PD = 3,000 lb, L = 6 ft, and h = 8 ft. Positive choices indicate tension. Negative choices indicate compression.
A pin-connected wood truss is loaded and supported as shown….
A pin-connected wood truss is loaded and supported as shown. Determine the axial force produced in member GH if PB = 1,000 lb, PC = 1,500 lb, PD = 3,000 lb, L = 6 ft, and h = 8 ft. Positive choices indicate tension. Negative choices indicate compression.
A wood member is loaded as shown. Using ASD, determine the a…
A wood member is loaded as shown. Using ASD, determine the adjusted bending strength, Fb’. Assume normal temperatures, no incising, and that all loads act in the directions shown. Ignore the weight of the member.Load:PD = 2,000 lbPL = 0 lbPLr = 0 lbPS = 0 lbPR = 0 lbPW = 7,000 lbPE = 9,000 lbQD = 1,500 lbQL = 4,000 lbQLr = 4,000 lbQS = 0 lbQR = 0 lbQW = 0 lbQE = 0 lbSpan:L = 9 ft Member size:4 x 12 Stress grade and species:No. 1 & Better Douglas Fir-Larch Unbraced length:lu = 0 ft Moisture content:MC > 19 percent
Use APA Technical Note Q225 entitled Load-Span Tables for AP…
Use APA Technical Note Q225 entitled Load-Span Tables for APA Structural-Use Panels and ASD procedures to answer the following question.The spacing of rafters in a roof is 16-in. o.c. Roof dead load = 12 psf. Snow load = 78 psf. Roof sheathing is to be an APA rated plywood STRUCTURAL I sheathing, and panels are to be oriented in the weak direction. The load is governed by deflection limits of L/360 for snow load and L/240 for total load. Only consider these limits. Assume multi-span, normal duration of load, dry conditions, and panels 24 inches or wider. Would a panel with a span rating of 32/16 be adequate?
Use APA Technical Note Q225 entitled Load-Span Tables for AP…
Use APA Technical Note Q225 entitled Load-Span Tables for APA Structural-Use Panels and ASD procedures to answer the following question.The spacing of joists in a floor system is 32-in. o.c. Floor dead load = 20 psf. Floor live load = 96 psf. Floor sheathing is to be an APA rated OSB sheathing, and panels are to be oriented in the strong direction. The load is governed by bending and shear for total load. Only consider these limits. Assume multi-span, normal duration of load, dry conditions, and panels 24 inches or wider. Would a panel with a span rating of 40/20 be adequate?