Determine the maximum actual deflection of the following bea…

Determine the maximum actual deflection of the following beam. Assume normal temperatures, bending about the strong axis, and no incising. Ignore the weight of the beam.Load:wD = 280 lb/ftwLr = 150 lb/ftLoad combination:D + LrSpan:L = 12 ftMember size:4 x 12Stress grade and species:Select Structural Douglas Fir-LarchUnbraced length:lu = 0Moisture content:MC > 19 percentLive load deflection limit:Allow. Δ ≤ L/360

Determine the ASD adjusted minimum modulus of elasticity, Em…

Determine the ASD adjusted minimum modulus of elasticity, Emin’, for the following beam. Assume normal temperatures, bending about the strong axis, and no incising. Ignore the weight of the beam.Load:PD = 440 lbPLr = 800 lbLoad combination:D + LrSpan:L = 6 ftMember size:4 x 8Stress grade and species:No. 1 & Better Douglas Fir-LarchUnbraced length:lu = 0Moisture content:MC > 19 percentLive load deflection limit:Allow. Δ ≤ L/360

A wood member is loaded as shown. Using ASD, determine the m…

A wood member is loaded as shown. Using ASD, determine the maximum axial stress in the member. Assume normal temperatures, no incising, and that all loads act in the directions shown. Ignore the weight of the member.Load:PD = 5,000 lbPL = 0 lbPLr = 0 lbPS = 0 lbPR = 0 lbPW = 8,000 lbPE = 8,500 lbQD = 2,500 lbQL = 2,000 lbQLr = 4,500 lbQS = 3,000 lbQR = 2,500 lbQW = 0 lbQE = 0 lbSpan:L = 12 ft Member size:4 x 12 Stress grade and species:No. 1 & Better Douglas Fir-Larch Unbraced length:lu = L/2 = 6 ft Moisture content:MC < 19 percent 

Determine the maximum actual deflection of the following bea…

Determine the maximum actual deflection of the following beam. Assume normal temperatures, bending about the strong axis, and no incising. Ignore the weight of the beam.Load:wD = 100 lb/ftwLr = 450 lb/ftLoad combination:D + LrSpan:L = 11 ftMember size:4 x 12Stress grade and species:No. 2 Douglas Fir-LarchUnbraced length:lu = 0Moisture content:MC > 19 percentLive load deflection limit:Allow. Δ ≤ L/360

Determine the maximum actual shear stress in the following b…

Determine the maximum actual shear stress in the following beam. Do not reduce the shear based on NDS Section 3.4.3. Assume normal temperatures, bending about the strong axis, and no incising. Ignore the weight of the beam.Load:PD = 360 lbPLr = 800 lbLoad combination:D + LrSpan:L = 13 ftMember size:4 x 12Stress grade and species:No. 2 Douglas Fir-LarchUnbraced length:lu = 0Moisture content:MC < 19 percentLive load deflection limit:Allow. Δ ≤ L/360

A wood column is pin connected at its top and bottom. Determ…

A wood column is pin connected at its top and bottom. Determine the controlling slenderness ratio, le/d, for the column. Assume normal temperatures, no incising, and that all loads are downward. Ignore the weight of the member.Load:PD = 4,000 lbPL = 4,000 lbPLr = 1,500 lbPS = 3,000 lbPR = 2,000 lbPW = 3,500 lbPE = 0 lbLength:L = 11 ftMember size:4 x 10Stress grade and species:No. 2 Douglas Fir-LarchUnbraced length:lu = L = 11 ftMoisture content:MC < 19 percent

Use APA Technical Note Q225 entitled Load-Span Tables for AP…

Use APA Technical Note Q225 entitled Load-Span Tables for APA Structural-Use Panels and ASD procedures to answer the following question.The spacing of joists in a flat roof is 19.2-in. o.c. Roof dead load = 15 psf. Snow load = 52 psf. Roof sheathing is to be an APA rated plywood sheathing, and panels are to be oriented in the strong direction. The load is governed by deflection limits of L/240 for snow load and L/180 for total load. Only consider these limits. Assume multi-span, normal duration of load, dry conditions, and panels 24 inches or wider. Would a panel with a span rating of 32/16 be adequate?

Use APA Technical Note Q225 entitled Load-Span Tables for AP…

Use APA Technical Note Q225 entitled Load-Span Tables for APA Structural-Use Panels and ASD procedures to answer the following question.The spacing of rafters in a roof is 16-in. o.c. Roof dead load = 12 psf. Snow load = 39 psf. Roof sheathing is to be an APA rated plywood STRUCTURAL I sheathing, and panels are to be oriented in the weak direction. The load is governed by deflection limits of L/360 for snow load and L/240 for total load. Only consider these limits. Assume multi-span, normal duration of load, dry conditions, and panels 24 inches or wider. Would a panel with a span rating of 32/16 be adequate?