Given: Wall height: 16 feetConcrete placement rate: 4 ft/hou…
Given: Wall height: 16 feetConcrete placement rate: 4 ft/hourInternal vibration depth < 4 ftAssume Cc and Cw as 1.0Temperature of concrete at placing: 70°FSlump: 4 inNormal-weight concrete (unit weight = 150 lb/ft3. The applicable concrete lateral pressure equation for the above given information for wall form design is: